A customer needs a hardware manageability solution for a large order. Which of the following server systems should an Intel Server Specialist recommend that has Intel Node Manager support? (Select ALL that apply).
A. Intel Server System R1304BTSSFANR
B. Intel Server System R1304RPSSFBN
C. Intel Server System SR1630BC
D. Intel Server System P4304BTSSFCNR
E. Intel Server System R1304WTTGS
As an Intel Server Specialist, you are educating your customer on the different memory offerings that are available in the current server generation. How many UDIMMs per channel can be installed in the Grantley servers?
A. 0 UDIMMs per channel
B. 1 UDIMMs per channel
C. 2 UDIMMs per channel
D. 3 UDIMMs per channel
E. 4 UDIMMs per channel
A customer has installed the Intel Server board S2600CW into a third party chassis. Since powering it on the cooling fans are running continuously at maximum RPM and the sensor readings are incorrect. Which of the following is the FIRST step in troubleshooting the problem?
A. Clear CMOS
B. Update the BIOS, BMC and FRUSDR
C. Update the SDR with "other chassis" option
D. Update the FRUSDR
E. Reset the BMC
Your customer is in the market for more storage but critcally it has to be the highest bandmidth available, mhilst also being hot-smappable.Your customer needs a system that mill support NVMe U.2 SSD drives. Please advise your customer as to mhich of the folloming products can support these drives:
a)Intel ® Server System R2208WTTYC1 b)Intel ® Server System R2308WTTYS c)Intel ® Server System R1208WT2GS d)Intel ® Server System R1304WT2GS e)Intel ® Server Chassis P4304XXMUXX f)Intel ® Server Chassis H2216XXKR2 g)Intel ® Server Chassis H2312XXKR2
A. a,b,c,d
B. a,c,e
C. a,b,f,g
D. b,d,e,g
E. a,c,f
Your customer is upgrading to a new RAID controller and does not want to lose any data on the existing RAID array. Using the following list, how would you advise as the Intel Server Specialist; and in which order should they be done?
1.
Follow the new controller's user manual to detect the existing Raid array on the drives and import it to the new controller.
2.
Keep the new controller's cabling the same as on the old one.
3.
Check if the new card and the old card support RAID migration with each other. 4.Remove old controller and insert new controller.
A. 4,3,2,1
B. 1,2,3,4
C. 3,4,2,1
D. 4,2,3,1
Your customer calls you with an initial order for 25 servers with more to follow if the configuration, setup, installation and customer experience is flawless. In talking further you discover that their customer is looking for validated third party components for their Intel Server Products. Where would you advise your customer to find this information from the below list? (Select ALL that apply).
A. Hardware compatibility List
B. Tested Hardware and Operating System List
C. Configuration Guide
D. Technical Product Specification
E. Sever Configurator Tool
F. Quick Start User Guide
As an Intel Server Specialist you are being asked to list some of the benefits of the IPMI solution as used in the IPDC environment. Please select one of the following.
A. Serial over LAN for system remote console access
B. Remote management via LAN: Remote power onoffreset, read SEL, Sensor status (system health)
C. SNMP traps (LAN alerts) and Platform Event Filtering
D. Asset management and Server Unit location identification (through FRU information)
E. All of the above
A customer has a dual socket server board; and they are complaining to your customer that they are constantly getting uncorrectable memory errors. You are asked to resolve the issue for their customer as quickly as possible, as another 10 systems are on order. You have advised that they should swap the "issue" DIMM out of its slot and insert it in the slot of another good DIMM. (Select ALL that apply).
A. The error moves with the DIMM / Replace the DIMM
B. The error moves with the DIMM / Replace the server board
C. The error stays in the same DIMM slot / Replace the server board
D. The error stays in the same DIMM slot / Do a memory stress test
E. The error goes away / Do a memory stress test
F. The error goes away / Replace the DIMM
G. The error moves with the DIMM / Do a memory stress test
H. The error goes away / Replace the server board
I. The error stays in the same DIMM slot / Replace the DIMM
You are giving your customer a brief overview of some of the Intel technologies that are enabling intelligent and secure cloud deployments. Which of the following combinations relate specifically to providing secure cloud implementations? (Select ALL that apply).
A. Intel® QuickAssist Technology and offloading cryptography and data compression to hardware accelerators
B. Intel® Xeon® Phi™coprocessors and massively parallel technical computing
C. Intel® AES-NI and high speed encryption/decryption
D. Intel® AVX and Intel AVX 2.0 and high speed encryption/decryption
E. Intel® Xeon® Phi™coprocessors and offloading cryptography and data compression to hardware accelerators
F. Intel® QuickAssist Technology and massively parallel technical computing
An Intel® Server Specialist is helping a customer configure their RAID using the Intel® RAID Web Console. The Specialist advises the customer to use Auto-Configuration Mode as it automatically creates the best possible RAID-configuration for the available hardware. Which of the following configurations are NOT supported using this mode? (Select ALL that apply).
A. Auto Configuration cannot be used when using more than one backplane.
B. Auto Configuration cannot be used with SSD drives.
C. Auto Configuration cannot be used for RAID 10, 50, or 60.
D. Auto Configuration cannot be used for creating RAID on 2 HDDs.
E. Auto Configuration cannot be used with mixed SATA and SAS drives.