DRAG DROP
Refer to the exhibit.

Match each callout to the Dell EMC PowerEdge server model shown.
Select and Place:

CORRECT TEXT
For a temporary migration task the CPU core count on the Dell EMC PowerEdge R640 server needs to be reduced to 8 because the installed application will not work due to license restrictions. Use the simulator to apply the change so the
application can be installed.
When you have finished using the simulator, click Next.

A. No answer
B. Place Holder
C. Place Holder
D. Place Holder
What is a systems management console solution optimized for monitoring and managing Dell enterprise and remote office hardware?
A. SupportAssist Enterprise
B. iSM
C. OpenManage Essentials
D. iDRAC9
What is the minimum number of components, beside the system board, required to POST?
A. PSUs, CPUs, and DIMMs as configured in BIOS
B. 1 PSU, 1 DIMM, and 1 CPU only
C. 1 PSU and 1 CPU only
D. 1 PSU, 1 CPU, 1 DIMM, and PERC SAS controller
A technician working with a Dell EMC PowerEdge 1 take corrective action?
A. Check the System Event Log Check PSU LED Reseat the PSU
B. Check the System Event Log Check PSU LED Do a virtual reseat of the iDRAC
C. Check the LCC Log Check PSU LED Reseat the CPU
D. Check the LCC Log Check PSU LED Reseat the PSU
What must be done before upgrading OMSA from the 32-bit to the 64-bit version?
A. Save the license file
B. Disable UAC
C. Back up the configuration
D. Uninstall the earlier version
A Dell EMC PowerEdge server has been updated with an LCC and iDRAC DUP to the latest firmware when performing a firmware rollback?
A. Both the iDRAC and the LCC can be rolled back
B. The LCC can be rolled back; the iDRAC cannot be rolled back
C. The iDRAC can be rolled back; the LCC cannot be rolled back
D. The iDRAC cannot be rolled back and the LCC cannot be rolled back
What is used by the Lifecycle Controller to directly back up the server profile on a 14G Dell EMC PowerEdge server?
A. Network share
B. vFlash SD card
C. USB Flash drive
D. IDSDM SD card
A technician is sent on-site to troubleshoot a server that produced an error message during the most recent POST, but then completed the POST and booted to the operating system. The user cannot remember the specific error and no entry was made in the error log relating to this error.
How can the technician find out what the error message was?
A. Access the Lifecycle Controller and view the last boot cycle video capture entry
B. Reload the BIOS firmware
C. Export the Server profile and analyze for any POST errors
D. Access the iDRAC and view the last boot cycle video capture entry
An engineer needs to install an additional PSU on an existing, single PSU Dell EMC PowerEdge R740. They complete the initial installation and cabling procedures. They connect an AC cable and the power distribution unit produces normal AC output. The engineer checks power management and sees that the new PSU is in the Failed state.
What task should be completed to troubleshoot this issue?
A. Confirm the System Input Power CAP is not set to Low
B. Set the PSU AC redundancy to 1+1
C. Set the PSU AC redundancy to 1+0
D. Verify the new PSU is the same type and wattage rating